This article will show you how to integrate your GentleWave unit(s) with TDO. By doing so, you will be able to view a log of procedures performed with your GentleWave unit(s).
Note: Please note this integration is only available in TDO 12.275a and newer and GentleWave software version 3.10:2485-1534 or later.
Note: While the Server Setup is the same for both generations, the steps to connect the console will be different for the older G3 GentleWave units. For the G3, please see GentleWave Integration Setup for G3
In order for the integration to work, the GentleWave must be able to send information to your TDO server. To make this possible, a service called ’TDO.ServerSvc’ runs on your server, ’listening’ for output from the GentleWave. To check if this service is running, go to Control Panel > Administrative Tools > Services, look for ’TDO.ServerSvc’ and make sure it is Running and its Startup Type is set to Automatic.

If you don’t see TDO.ServerSvc at all, you’ll need to install it by running TDOfficeData\TDO.ServerSvc\InstallServerSvc.bat as Administrator.
Note: The InstallServerSvc.bat file must be run on the local drive where TDO is installed on the server. It cannot be run from a mapped drive.
NOTE: You must also open port 8739 to inbound and outbound traffic in Windows Firewall. To do this, Open Firewall defender> Advanced Settings> Inbound and outbound (create a new rule for both> New rule> port> TCP and port 8739> ALLOW CONNECTION> all three checked DOMAIN PRIVATE and PUBLIC> Name: GentleWave Port, and Description: Firewall port
Log into TDO and open Setup > Site Configuration > Edit Control Table > Application Settings. Click on Integrated Devices. Enter a Device name (e.g. GW1234, GWOP1) and serial number for your GentleWave(s) as shown below, Make sure the Enabled checkbox is checked, then close the window to save. If you are unable to access this window, please contact support.

Note: If you're unable to connect, contact your IT personnel and ensure your router has 2.4 or 5GHz and 20MHz channels enabled



Your GentleWave should now be connected to TDO!
If the console still displays Unregistered, check that you have correctly entered the GentleWave serial number in the TDO Control Table.
Using the GentleWave with TDO: Using TDO with the GentleWave Procedure
Article ID: 920
Created: April 20, 2023
Last Updated: September 2, 2025
Author: TDOKB2 [IT@tdo4endo.com]
Online URL: https://kb.tdo4endo.com/article.php?id=920